Resource Library · GMP 11

Calibration Intervals

Series
GMP 11
Revision
May 2019
Pages
10
File
gmp-11-calibration-intervals-20190506.pdf
SHA-256
fe8daac7ab72…

Inside this document

Every page is full-text indexed — open a page directly in the PDF viewer.

Page 1 GMP 11 – 2019 Page 1 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.6969 - 201 9 GMP 11 Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Labora... Open at page → Page 2 GMP 11 – 2019 Page 2 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.6969 - 201 9 Prerequisites Calibration history and valid calibration certificates, with suitable calibration pr... Open at page → Page 3 GMP 11 – 2019 Page 3 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.6969 - 201 9 evaluation of performance, calibration intervals are determined to meet a 99 % reliability target.... Open at page → Page 4 GMP 11 – 2019 Page 4 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.6969 - 201 9 calibration status prior to regular management reviews so that adequate resources are available to... Open at page → Page 5 GMP 11 – 2019 Page 5 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.6969 - 201 9 4 Calibration Intervals for the Laboratory Scope As this document is a template, the l aboratory m... Open at page → Page 6 GMP 11 – 2019 Page 6 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.6969 - 201 9 All other weighing processes have incorporated measurement control procedures and control charts t... Open at page → Page 7 GMP 11 – 2019 Page 7 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.6969 - 201 9 Table 3. Recommended calibration intervals for mass standard s for Echelon III calibrations. Stand... Open at page → Page 8 GMP 11 – 2019 Page 8 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.6969 - 201 9 Table 5. Recommended calibration intervals for length standards. Standards Initial Interval (month... Open at page → Page 9 GMP 11 – 2019 Page 9 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.6969 - 201 9 Volume Secondary Parameters Table 8. Recommended calibration intervals for volume secondary parame... Open at page → Page 10 This page is intentionally blank. This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.6969-2 019 Open at page →