Workbench

Tools & Calculators

Working calculators for daily metrology — conversions, uncertainty budgets and acceptance decisions. All calculations run locally; nothing is stored.

Unit Converter

Full-precision conversion factors; temperature converts through kelvin.

Result
0.039370079 in

Uncertainty Budget (GUM)

Enter each component in the SAME unit as the measurand. Values are converted to standard uncertainties by the distribution divisor, scaled by the sensitivity coefficient, then combined by root-sum-of-squares (uncorrelated inputs).

Source Value (±) Distribution Coeff |cᵢ| uᵢ
Combined standard uncertainty u꜀ · Expanded uncertainty U = k·u꜀
Enter at least one numeric component

k = 2 corresponds to ≈95 % coverage for a normal distribution with large effective degrees of freedom. If one rectangular component dominates or repeats are few, see the GUM (Welch–Satterthwaite) before quoting 95 %.

TUR & Guard Band Calculator

Test uncertainty ratio and ILAC-G8 guarded acceptance — both inputs as symmetric half-widths in the same unit.

Test uncertainty ratio
Enter tolerance and uncertainty

Uncertainty Rounding & Significant Figures

GUM 7.2.6 convention: report the expanded uncertainty to two significant figures and round the measured value to the same decimal place.

Reported result
Enter value and uncertainty

Calibration Interval Analysis

Simplified exponential-reliability adjustment (NCSLI RP-1 / ILAC-G24 style) from as-found data for one instrument family. Adjustment factor capped at ×0.5–×2.

Recommended interval
Enter interval, counts and target

Thermal Expansion Correction

Dimensional results refer to 20 °C (ISO 1). ΔL = α · L · (T − 20 °C).

Expansion at part temperature
Enter length and temperature

These tools support, but do not replace, a documented uncertainty evaluation per the GUM and your laboratory's procedures.