Resource Library · SOP 16

Volume Transfer Flasks

Series
SOP 16
Revision
May 2019
Pages
10
File
sop-16-volume-transfer-flasks-20190508.pdf
SHA-256
d1bee94a8fea…

Inside this document

Every page is full-text indexed — open a page directly in the PDF viewer.

Page 1 SOP 16 – 2019 Page 1 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 SOP 16 Standard Operating Procedure for Calibration of Measuring Flasks Volume Transfer Method 1 In... Open at page → Page 2 SOP 16 – 2019 Page 2 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 Verify that the operator has had specific training and is proficient in SOP 16, GMP 3, GMP 7, and i... Open at page → Page 3 SOP 16 – 2019 Page 3 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 Calibrated standard buret(s) of 10 mL (or 1 20 minim 1 ) capacity. These standards are typically ma... Open at page → Page 4 SOP 16 – 2019 Page 4 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 the flask. Note that some small amount of water will remain in the flask. Each flask to be calibrat... Open at page → Page 5 SOP 16 – 2019 Page 5 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 the test volume during calibration. Repeatability problems may be due to contamination, poor menisc... Open at page → Page 6 SOP 16 – 2019 Page 6 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 The volumetric standards are typically made of borosilicate glass. If borosilicate flasks are calib... Open at page → Page 7 SOP 16 – 2019 Page 7 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 Check standard observations are used to calculate the standard deviation of the measurement process... Open at page → Page 8 SOP 16 – 2019 Page 8 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 temperature, water temperature at time of test, barometric pressure, relative humidity, and any out... Open at page → Page 9 SOP 16 – 2019 Page 9 of 9 This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 Appendix A Calibration of Measuring Flasks (Volume Transfer Method) Laboratory data and conditions:... Open at page → Page 10 This page is intentionally blank. This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383-20 19 Open at page →