Resource Library · SOP 18
Volume Transfer Field Standard Using Slicker
Inside this document
Every page is full-text indexed — open a page directly in the PDF viewer.
Page 1
SOP 18 – 2019 Page 1 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 SOP 18 Standard Operating Procedure for Calibration of Graduated Neck-Type Metal Volumetric Field...
Open at page →
Page 2
SOP 18 – 2019 Page 2 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 resolution and repeatability on a 20 L or 5 gal test measure with 1 in 3 graduations. For graduat...
Open at page →
Page 3
SOP 18 – 2019 Page 3 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 Table 2. Laboratory environmental and equilibrated water conditions. Procedure Temperature Relati...
Open at page →
Page 4
SOP 18 – 2019 Page 4 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 followed by a 10 s drain, with the measure held at a 10 degree to 15 degree angle from vertical,...
Open at page →
Page 5
SOP 18 – 2019 Page 5 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 Position the unknown vessel beneath the slicker-plate standard drain valve or piping to be sure n...
Open at page →
Page 6
SOP 18 – 2019 Page 6 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 The reading of Run 1 is used to adjust the scale of the vessel, if necessary, to the correct read...
Open at page →
Page 7
SOP 18 – 2019 Page 7 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 calculate a mean value by combining “as found” and “as left” values when adjustments are made). 4...
Open at page →
Page 8
SOP 18 – 2019 Page 8 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 level of confidence. See SOP 29 for the complete standard operating procedure for calculating the...
Open at page →
Page 9
SOP 18 – 2019 Page 9 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 Table 3. Example uncertainty budget table . Uncertainty Component Description Symbol Source Typic...
Open at page →
Page 10
SOP 18 – 2019 Page 10 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 identifying markings, tolerances (if appropriate), laboratory temperature, water temperature(s)...
Open at page →
Page 11
SOP 18 – 2019 Page 11 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 Appendix A Volume Transfer Data Sheet Laboratory data and conditions: Vessel Owner Operator Vess...
Open at page →
Page 12
This page is intentionally blank. This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383-20 19
Open at page →