Resource Library · SOP 18

Volume Transfer Field Standard Using Slicker

Series
SOP 18
Revision
May 2019
Pages
12
File
sop-18-volume-transfer-field-standard-using-slicker-20190508.pdf
SHA-256
21502dc918d6…

Inside this document

Every page is full-text indexed — open a page directly in the PDF viewer.

Page 1 SOP 18 – 2019 Page 1 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 SOP 18 Standard Operating Procedure for Calibration of Graduated Neck-Type Metal Volumetric Field... Open at page → Page 2 SOP 18 – 2019 Page 2 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 resolution and repeatability on a 20 L or 5 gal test measure with 1 in 3 graduations. For graduat... Open at page → Page 3 SOP 18 – 2019 Page 3 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 Table 2. Laboratory environmental and equilibrated water conditions. Procedure Temperature Relati... Open at page → Page 4 SOP 18 – 2019 Page 4 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 followed by a 10 s drain, with the measure held at a 10 degree to 15 degree angle from vertical,... Open at page → Page 5 SOP 18 – 2019 Page 5 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 Position the unknown vessel beneath the slicker-plate standard drain valve or piping to be sure n... Open at page → Page 6 SOP 18 – 2019 Page 6 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 The reading of Run 1 is used to adjust the scale of the vessel, if necessary, to the correct read... Open at page → Page 7 SOP 18 – 2019 Page 7 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 calculate a mean value by combining “as found” and “as left” values when adjustments are made). 4... Open at page → Page 8 SOP 18 – 2019 Page 8 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 level of confidence. See SOP 29 for the complete standard operating procedure for calculating the... Open at page → Page 9 SOP 18 – 2019 Page 9 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 Table 3. Example uncertainty budget table . Uncertainty Component Description Symbol Source Typic... Open at page → Page 10 SOP 18 – 2019 Page 10 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 identifying markings, tolerances (if appropriate), laboratory temperature, water temperature(s)... Open at page → Page 11 SOP 18 – 2019 Page 11 of 11 This publ ication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383 - 2019 Appendix A Volume Transfer Data Sheet Laboratory data and conditions: Vessel Owner Operator Vess... Open at page → Page 12 This page is intentionally blank. This publication is available free of charge from: https://doi.org/10.6028/NIST.IR.7383-20 19 Open at page →