Resource Library · SP 250
Gamma Ray Emitting Brachytherapy Sources
Inside this document
Every page is full-text indexed — open a page directly in the PDF viewer.
Page 1
NBSMeasurement Services: NEWNIST Apr i1 PUBLICATION 20,1989 JamesT.Weaver ThomasP.Loftus RobertLoevinger U.S.DepartmentofCommerce NationalBureauofStandards
Open at page →
Page 2
CenterforRadiationResearch TheCenterforRadiationResearchisamajorcomponentoftheNationalMeasurementLaboratoryintheNational BureauofStandards. TheCenterprovidestheNationwithstandardsandmeasurementservicesforionizing radiati...
Open at page →
Page 3
NBSMEASUREMENTSERVICES: CALIBRATIONOFGAMMA-RAY- EMITTINGBRACHYTHERAPYSOURCES JamesT.Weaver ThomasP.Loftus RobertLoevinger CenterforRadiationResearch NationalMeasurementLaboratory NationalBureauofStandards Gaithersburg,MD...
Open at page →
Page 4
LibraryofCongressCatalogCardNumber:88-600609 NationalBureauofStandardsSpecialPublication250-19 Natl.Bur.Stand.(U.S.),Spec.Publ.250-19,60pages(Dec.1988) CODEN:XNBSAV Commercialproducts—materialsandinstruments—areidentifie...
Open at page →
Page 5
PREFACE ThecalibrationandrelatedmeasurementservicesoftheNationalBureau ofStandardsareintendedtoassistthemakersandusersofprecision measuringinstruments inachievingthehighestpossiblelevelsof accuracy,quality,andproductivit...
Open at page →
Page 6
Abstract .Thecalibration ofsmallradioactivesourcesusedforinterstitial radiationtherapy(brachytherapy )isperformed intermsofthephysical quantitiesexposureorairkerma. Thecalibrations arelistedinNBSSpecial Publication 250as...
Open at page →
Page 7
TableofContents Page Abstract iv ListofTables vi ListofFigures viii Foreword ix 1.Introduction 1 1.1.Description oftheservice 1 2.Designphilosophyandtheory 5 3.Thelong-half-life radionuclides --^^^Csand^^Co ^ 3.1.Therepl...
Open at page →
Page 8
ListofTables Page 1-1.Characteristics oftheradionuclides acceptedforbrachytherapy calibration 3 1-2.Rateconstantsforthebrachytherapy radionuclides calibrated at NBS 4 3-1.EngravingonNBSstandard ^^"^Csand^^Cosources 9 3-2...
Open at page →
Page 9
ListofTables(Continued) Page 4-1.Constancycheckofaluminumreentrantionizationchamberforthe years1977through1987 22 4-2.Dimensionsandmaterialsfortwotypesof^"^^Irseeds 23 4-3.Reentrantchambercalibration factorsatSTPfor^'^^r...
Open at page →
Page 10
ListofFigures Page Figure1.Calibration rangeforbrachytherapy sources 6 Figure2.Cross-section viewofthepolystyrenebasethatsupportsthe 2.8-litersphericalaluminumionizationchamber 10 Figure3.Aluminumreentrantionizationchamb...
Open at page →
Page 11
FOREWORD NBSSpecialPublications 250-16and250-19 canbeconsideredmonuments totheskillanddedication ofThomasP.Loftus. TomcametotheRadiological EquipmentSectionofNBSin1951,workingunderDr.ScottSmith,Section Chief,andDr.H.0.Wy...
Open at page →
Page 13
1.Introduction Thisreportdescribesthestatusofthecalibrationservicefor brachytherapy gamma-raysources,asofDecember1987. Section 1definesthe physicalquantitiesexposureandairkerma,intermsofwhichthecalibrations areperformed;...
Open at page →
Page 14
Then X=dQ/dm . (1) TheSIunitofexposureisthecoulombperkilogram(C/kg);thespecialunit ofexposure,theroentgen(R),isequalto2.58x10"'+C/kg(exactly). The ionizationarisingfromtheabsorptionofbremsstrahlungemittedbythe secondarye...
Open at page →
Page 15
multiplicative constantisneededtoconverttheformerquantitytothe latter. Whilethetextissimplified byusingtheword"exposure"toimply bothphysicalquantities, airkermaisnamedexplicitlywhennumericalmagni- tudesareinvolved,orwhen...
Open at page →
Page 16
Brachytherapy sourcesaregamma-ray-emitting radionuclides encapsulated inasuitablemetal,ordinarilychosentobeinnocuoustotissue. Theycome inavarietyofforms,oftenreferredtoas"seeds,""tubes,"or"needles," butsometimescomingint...
Open at page →
Page 17
2. Oesignphilosophyandtheory Rrachytherapy sourcesareprovidedwithcalibrations internsofexposure rateatonemeterperpendicular totheaxisofthesource,correctedto vacuum. Thecalibration isbasedonmeasurements ofotherbrachythera...
Open at page →
Page 18
6
Open at page →
Page 19
Figure1.Calibration rangeforbrachytherapy sources. y A.Sphericalionizationchamberfor^^Coand^^'^Cssources. B.Sourceholderfor^^Coand^^^Cssources. C.Slideforsourceholder. Distancefromsourcecentertochambercenteris variablefr...
Open at page →
Page 20
3. Thelong-half-life radionuclides --^^^Csand^QCo 3.1.Thereplacementmethod Small-source calibration bythereplacementmethodconsistsof measurement oftheradiationfromastandardsourceS,andthen,after replacingthestandardwithth...
Open at page →
Page 21
Table3-1.EngravingonNBSstandard ^^'^Csand^^Cosources. Engraving on Sourceidentity Cylinderwall Endwall SOCo"500" ICN 2-9-76 995 500MC CO-60 60Co"100" CO-60 100MC 996 2-9-76 ICN I37cs "500" Csl37 N.C.C. D49 I37cs "50" Csl...
Open at page →
Page 22
Ttft83798 CONNECTORWITH frreinsolation Figure ?..Cross-section viewofthepolystyrenebasethatsupportsthe 2.8-litersphericalaluminumionizationchamber. Italsoprovides high-voltage insulation, andsupportstheguardringandthe co...
Open at page →
Page 23
Table3-3. Typicalrecombination dataforthe2.8-litersphericalaluminum ionizationchamber(HB806:27). Thepolarityofthechamberwall isnegative. Thetablegivesthereciprocal ofthenormalized current. Collection Normalizedvaluesfort...
Open at page →
Page 24
Therestriction onthelengthofasourcetobecalibrated isonlythatitfit intothetrough. Intheworstcase,ifalltheactivityofasourcecapsule 50mminlengthwereconcentrated atoneend(25mmoffcenter),the geometrical error,neglectingobliqu...
Open at page →
Page 25
Table3-5.Relativeexposureratesfor^^'^Csworkingstandards,basedon1967 measurements. Source Relativeexposurerates "son" ion "50" 10.80 "5" 0.932 3.2.2. Presentstandards TheNBSexposurestandardsfor^^Coand i^tq^ gammarayswerer...
Open at page →
Page 26
Inadditiontotheoriginalmeasurement in1967,the"500"sourcehas beencheckedtwiceinopen-airgeometry, in1978andin1983. Table3-7gives theoriginalmeasurements andtheexposureratescorrectedtothe1974and 1986exposurestandards. Table...
Open at page →
Page 27
Table3-9. Bestvaluesfor^^'^Csworkingstandardsbasedonmeanofthree measurements ofthe"500"sourceintheperiod1967-1983. The dataareconsistentwiththe1986exposurestandard,andare correctedto1986Jan01usingahalf-lifeof30.0years. S...
Open at page →
Page 28
3.3.2. Presentstandards Comparedto^^"^Cs,therearenowfewrequestsfor^°Cosmall-source calibrations. Onereasonperhapsistherelativelyshorthalf-lifefor^°Co ^'^^y)' Theshorthalf-lifefor^^Coalsoposestheproblemof maintainingstand...
Open at page →
Page 29
Table3-12. MeanexposurerateforthetwoICN^°Cosources,adjustedtothe 1986standard. Source ICN Meanexposurerate 19%Janni (mRm2/h) 100 500 26.39±0.1% 141.3 Asshownintable3-11,theICN100sourcewasmeasuredonthree occasions,withati...
Open at page →
Page 30
3.4.Uncertaintyassessmentfor^^^Csand""^Cosources Themethodofuncertaintyassessmentusedherefollowstherecommendation oftheComiteInternational desPoidsetMesures(CIPM). Theuncertainty estimatesareoftwokinds. Conventional stat...
Open at page →
Page 31
Table3-14.Uncertaintyanalysisfor^^'^Csand^^Cosourcecalibration by substitution. A B {%) (%) (a)Measurement ofsecondaryworkingstandard usingprimarygraphitestandardchambers. Volume n.l 0.05 Charge 0.04 0.1 Timing 0.03 0.03...
Open at page →
Page 32
NotestoTable3-14 Theuncertaintyestimatesareattheone-sigmalevel,andareinpercent. The columnsheadedAandBrefertotheestimatesdescribed inthetextasTypeA andTypeB. Chargeincludesuncertainties forbothvoltageandcapacitance. Aird...
Open at page →
Page 33
4. Theshort-ha1f-1iferadionuclides --^^^rand ^^Sj 4.1.Thereentrantchamber Areentrant-type (well-type) ionizationchamber,illustrated infigure3, isemployedinthecalibration ofsmallsourcesoftheseradionuclides. The chamberisa...
Open at page →
Page 34
Incontrasttothecalibration ofsmallsourcesof^°Coand^'^^Cs,where thereferenceforcalibration residesinsourcestandards,thereferencefor exposurestandardization of^^^Irand ^^Sj sourcesresidesinthecalibration factorsforthereent...
Open at page →
Page 35
Sincethealuminumsphereisathighpotential, itisnecessarytouse aninsulatingholderwhenputting ^'^'^Irsourcesintothebrassreentranttube. Theholderisaglassvial65mminlengthwithanouterdiameterof9.2mm andawallthicknessof1.4mm(0.29...
Open at page →
Page 36
Theionizationcurrentsproducedby^'^^Irsourcesinthereentrant chambermustbecorrectedforrecombination. Testsshowthatatacollection potential of1100volts,andionizationcurrentsuptoabout80pA,the recombination correction isconsta...
Open at page →
Page 37
Themeanofthedecay-corrected currentsis31.21pA(usingthehalf-life 73.83days). Thereentrantionizationchambercalibrationfactorforthe stainless-steel-clad ^'^^Irsourcesis3.209kRm^/As,andsincethe ionizationcurrentislessthan80p...
Open at page →
Page 38
Table4-5. ^^^lseedtypesandtheirassociatedreentrant ionization-chamber calibration factors. 3-MCo. Model No. Type Details* Calibrationfactors Before1986 1986Jan01 (kRm2/As) (kRm2/As) 6701 Gold- 1251adsorbedontworesin 3.85...
Open at page →
Page 39
Duetoexperimental difficulties, longperiodsoftimeelapsedbetween theinitialfree-air-chamber andreentrant-chamber measurements forsomeof the1251seeds. However,forthemostpart,theFAC-reentrant chamber measurement intervalwas...
Open at page →
Page 40
Forthepurposeofcalculatingtheuncertainties intheattenuation corrections, thevalue(1.5±0.7) x10~3cm~iisadopted. Becauseofthe assumptionofexponential attenuation, thefractionaluncertainty intheair attenuationcorrectionfact...
Open at page →
Page 41
2.Withthehigh-voltaye supplyturnedoff,thehiyh-voltage connection tothereentrantchambershouldbechecked. Itisgoodpracticetoturnthe screwthatactsastheconnectortothechamberwallandtorotatetheclip connectingthehigh-voltagewire...
Open at page →
Page 42
9.Withtheelectrometer feedbackshorted,turnoffthehighvoltage switchandreturnthesourcetoitsdrawerinthesafe. Thesourceis unloadedfromthethistletubebylettingitslideoutintothewhiteplastic tray. 10.Checkthatthehighvoltageisoff...
Open at page →
Page 43
Importantinformationalwaystoberecorded isasfollows: 1.Personperformingcalibration. 2.Date. 3.Equipment(Indicateifsame,ordifferentfrom,equipmentused previously) . 4.Capacitance (Identify,referencecalibration). 5.HVandpola...
Open at page →
Page 44
14.Applytheappropriaterecombination correctiontothecomputed ionizationcurrent. 15.Multiplythemeancorrectedionizationcurrentbytheappropriate reentrantchambercalibrationfactortodeterminetheexposure(or airkerma)rateatonemet...
Open at page →
Page 45
Table4-7.Uncertaintyanalysisfor^^^Irsourcecalibrationwiththe reentrantchamber. A B (%) {%) Measurementofarrayofseedsusing graphitestandardchambers Volume 0.01 Charge 0.03 0.05 Timing 0.01 Airdensity 0.03 0.05 Recombinati...
Open at page →
Page 46
Table4-7.Continued (%) {%) Measurement ofsingleunknownsource1n reentrantchamber Charge 0.05 0.1 Timing 0.01 Airdensity 0.05 0.1 Recombination loss 0.1 Leakageandradiationbackground 0.02 Reproducibility inreentrantchamber...
Open at page →
Page 47
Table4-8.Uncertaintyanalysisfor I25j sourcecalibrationwiththe reentrantchamber. A1 1 AU-•mark Ag-•wire INO-mark A n D D A A D D A D ts (/o) (/o) [lo) (A) Sourcearray Exposurerate U.1)/ 0.07 0.33 0.0/ 0.33 Leakage 0.4 0.2...
Open at page →
Page 48
NotestoTable4-8. Theuncertaintyestimatesareattheone-signalevel,andareinpercent. The columnsheadedAandBrefertotheestimatesdescribedinthetextasTypeA andTypeB. ThecolumnsheadedAu-mark,Ag-wire,andNo-markrefertothegold-narker...
Open at page →
Page 49
Basedontheassessment ofuncertainties describedhere,thefollowing areadoptedastheoveralluncertainties forsourcescalibratedwiththe reentrantionizationchamber: Theoveralluncertainty isconsideredtohavetheapproximatesignifican...
Open at page →
Page 50
Radiationbadgesmustbewornatalltimeswhileworkingwithbrachy- therapysources. Inparticular, fingerbadgesmustbewornwhenthesources arebeingmanipulated inanymanner. Therateconstantslistedintable1-2 canbeusedtoestimateexposures...
Open at page →
Page 51
References [1]NBS,NBSCalibrationServicesUsersGuide1986-88 .NBSSpecial Publication250,G.A.Uriano,etal.,Editors,U.S.Departmentof Commerce,NationalBureauofStandards, U.S.GovernmentPrintingOffice, Washington, D.C.July1986. [...
Open at page →
Page 52
[14]Loftus,T.P.,Exposurestandardization ofiodine-125seedsusedfor brachytherapy. J.Res.Nat.Rur.Stand.(U.S.)89,295-303(1984). [15]Kubo,H.,Exposurecontribution fromTiKxraysproducedinthetitanium capsuleoftheclinical1-125seed...
Open at page →
Page 53
APPENDIXA AttachmentconcerningadjustmentofNBSexposurerates. ExposurerateswereadjustedatNBSon1986Jan01totakeintoaccount recentrefinements insomeofthephysicalparameters .Exposureratesin allreportsissuedafter1986Jan01arelow...
Open at page →
Page 55
APPENDIXB DG7890/86 TFN234668 DB851:156-163 1986May9 U.S.DEPARTMENTOFCOMMERCE NATIONALBUREAUOFSTANDARDS GAITHERSBURG ,MARYLAND20899 ReportofExposure-rateMeasurement of OneCesium-137SourceEngraved3M151267 Submittedby Colo...
Open at page →
Page 56
DG7890/86 1986May9 Page2of3 Thecylindricalsourceengraved3M151267isapproximately 20mminlength and3mmindiameter. Nodetermination ofradionuclidic puritywas performed . Thestrengthofthissourceisgivenintermsoftheexposureratea...
Open at page →
Page 57
AttachmentconcerningadjustmentofNBSexposurerates. ExposurerateswereadjustedatNBSon1986Jan01totakeintoaccount recentrefinements insomeofthephysicalparameters. Exposureratesin allreportsissuedafter1986Jan01arelowerthanthee...
Open at page →
Page 59
APPENDIXC DG8798/87 TFN240725 DB875:151-161 1987Dec17 U.S.DEPARTMENTOFCOMMERCE NATIONALBUREAUOFSTANDARDS GAITHERSBURG. MD20899 Page 1of3 REPORTOFAIR-KERMA-RATEMEASUREMENT Iridium-192Seed Manufacturedby For BestIndustries...
Open at page →
Page 60
DG8798/87 1987Dec17 1 Page2of3 TheAmericanAssociationofPhysicistsinMedicinehasrecommendedthat air-kermastrengthbegivenintheunitsmicrograysmeterssquaredperhour ("Specification ofBrachytherapy SourceStrength",AAPMReportNo....
Open at page →
Page 61
AttachmentconcerningadjustmentofNBSexposurerates. ExposurerateswereadjustedatNBSon1986Jan01totakeintoaccount recentrefinements insomeofthephysicalparameters. Exposureratesin allreportsissuedafter1986Jan01arelowerthanthee...
Open at page →
Page 63
APPENDIXD DG8844/88 U.S.DEPARTMENTOFCOMMERCE Page 1of2 TFN241000 NATIONALBUREAUOFSTANDARDS DB875:162-200 GAITHERSBURG ,MD20899 DB882:4-12 1988Mar08 REPORTOFAIR-KERMA-RATEMEASUREMENT Model6711Iodine-125Seed LotNo.ISW-804...
Open at page →
Page 64
DG8844/88 1988Mar08 Page2of2 TheAmericanAssociationofPhysicistsinMedicinehasrecoiiunendedthatair kermastrengthbegivenintheunitsmicrograysmeterssquaredperhour ("Specification ofBrachytherapy SourceStrength",AAPMReportNo.2...
Open at page →
Page 65
AttachmentconcerningadjustmentofNBSexposurerates. ExposurerateswereadjustedatNBSon1986Jan01totakeintoaccount recentrefinements insomeofthephysicalparameters. Exposureratesin allreportsissuedafter1985Jan01arelowerthanthee...
Open at page →
Page 67
NBS-n4A(REV.2-8C) U.S.DEPT.OFCOMM. 1,PUBLICATIONOR 2.PerformingOrgan.ReportNo,3.PublicationDate BIBLIOGRAPHICDATA RPPnRTMO Decenber1988 SHEET(Seeinstructions) NBS/SP-250/19 4.TITLEANDSUBTITLE NBSMeasurementServices: Cali...
Open at page →
Page 71
THESP250SERIESONNBSMEASUREMENTSERVICES* SP250-1 SpectralRadianceCalibrations SN003-O03-02792-8 $3.50 SP250-2 FarUltravioletDetectorStandards PB87227609 SP250-3 RadiometricStandardsintheVacuum Ultraviolet SN003-003-02806-...
Open at page →
Page 72
U.S.DepartmentofCommerce NationalBureauofStandards Gaithersburg,MD20899 OfficialBusiness PenaltyforPrivateUse$300
Open at page →