Resource Library · SP 250
X Ray and Gamma Ray Measuring Instruments
Inside this document
Every page is full-text indexed — open a page directly in the PDF viewer.
Page 1
CalibrationofX-Rayand nist_^^ Gamma-RayMeasuring Publication Instruments 250-58 PaulJ.LampertI MichelleO'Brien
Open at page →
Page 2
fhe NationalInstituteofStandardsandTechnologywasestablished in1988byCongressto"assistindustryin thedevelopmentoftechnology ...neededtoimproveproductquality,tomodernizemanufacturingprocesses,to ensureproductreliability ....
Open at page →
Page 3
NISTSpecialPublication250-58 NISTMEASUREMENTSERVICES: CalibrationofX-RayandGamma-Ray IVIeasuringInstruments PaulJ.Lamperti MichelleO'Brien IonizingRadiationDivision PhysicsLaboratory NationalInstituteofStandardsandTechno...
Open at page →
Page 4
Certaincommercial entities,equipment,ormaterialsmaybeidentifiedinthisdocument inorderto describeanexperimentalprocedureorconceptadequately.Suchidentification isnotintendedtoimply recommendation orendorsementbytheNational...
Open at page →
Page 5
Foreword ThiseditionoftheNationalInstituteofStandardsandTechnology(NIST)SpecialPublication 250SeriesisarevisiontotheNBSSpecialPublication250-16CalibrationofX-Rayand Gamma-RayMeasuringInstrumentsdocument.Theoriginalworkha...
Open at page →
Page 6
Abstract TableofContents Page ii Foreword iii Listoftables iv Listoffigures vii 1.0 Scope 1 2.0 Referencesdocuments 1 2.1 Internationalorganizationforstandardization 2.2 NationalInstituteforStandardsandTechnology 3.0 Ter...
Open at page →
Page 7
8.3 Ionizationcurrentmeasurement-console equipment 42 8.3.1X-raycalibrationdataacquisitionsystem 42 8.3.2Gamma-raycalibrationdataacquisitionsystem 45 8.4 Pre-calibration testsofinstruments 46 8.4.1 Charger/reader lineari...
Open at page →
Page 8
ListofTables Table4-1. Calibrationconditionsforx-rayandgamma-raymeasuring instruments Table4-2. Mammographyx-raybeam-qualityparameters Table4-3. ISOX-RayBeamQualityParameters Table6-1. DescriptionoftheNISTx-raysystems Ta...
Open at page →
Page 9
Table6-13. CorrectionfactorsfortheAttixfree-airionization chamber 30 Table6-14. ResultsofthecomparisonoftheLampertistandardwiththe BIPMstandard 32 Table6-15. ResultsofthecomparisonoftheRitzstandardwiththeBIPM standard 32...
Open at page →
Page 10
Table8-3. High-energyPantakunitvoltagecalibration 45 Table8-4. Temperatureprobeparametersforthegammasource calibrationranges 46 Table10-1. AnalysisofthreeNISTcheckchambersfortheperiod of1979to1997 53 Table11-1. Uncertain...
Open at page →
Page 11
ListofFigures Fig.4-1 . Graphofgeneratingconstantpotentialagainsthalf-valuelayerfor thebeamqualitiesusedinthex-raycalibrationrange 7 Fig.4-2. Graphofhomogeneitycoefficientsagainstaluminumhalf-value layerfortheL,M,HandSfi...
Open at page →
Page 13
1. Scope 1.1 Thisdocumentdescribesthex-rayandgamma-raycalibrationservicesprovidedbythe IonizingRadiationDivision,RadiationInteractionsandDosimetryGroupattheNational InstituteofStandardsandTechnology(NIST).Thecalibrationa...
Open at page →
Page 14
3.1.2beamquality-usedtorefertoaspecificx-raybeamwithacharacteristichalf-valuelayer andproducedbyaconstantpotentialkilovoltage. 3.1.3 calibration -theprocesswherebytheresponseofadosimeterormeasuringinstrument is character...
Open at page →
Page 15
4. Calibrationservice Thisreportdescribesthestatusofthecalibrationserviceforx-rayandgamma-ray measuringinstruments,asofJanuary1999.Thephysicalquantitiesair-kermaandexposure, calibrationbysubstitution,andthepropertiesofth...
Open at page →
Page 16
stoppedinair.TheSIunitofexposureisthecoulombperkilogram(C/kg);thespecialunitof exposure,theroentgen(R),isequaltoexactly2.58E-4C/kg.Theionizationarisingfromthe absorptionofbremsstrahlungemittedbythesecondaryelectronsisnot...
Open at page →
Page 17
Thequalitiesforeachgroupwerechosensothatrelativelysmoothcurvesresultforthegraphof tubepotentialversusHVL.Table4-1givesacompletelistingofbeamcodescurrentlyavailable atNIST.TheNBSbeamcodesusedpriortoJanuary1986arelistedinA...
Open at page →
Page 18
Table4-1.Calibrationconditionsforx-rayandgamma-raymeasuringinstruments Beam code' AdditionalFilteration Half-valuelayerHomogeneity coefficient " Effective energy'' Distance Al Cu Sn Pb Al Cu Al Cu (keV) (cm; (mm)(mm)(mm)...
Open at page →
Page 19
Fig.4-1Graphofgeneratingconstantpotentialagainsthalf-valuelayerforthebeamqualities usedinthex-raycalibrationrange.Thecurvesforhalf-valuelayersmeasuredincopperand aluminumareshownforthelight(L),moderate(M),heavy(H)andspec...
Open at page →
Page 20
1 IMINI X s 0.01 0.10 1.00 10.00 100.00 Half-ValueLayer(mmAl) Fig.4-2.Graphofhomogeneitycoefficientsagainstaluminumhalf-valuelayerfortheL,M,H andSfiltrations.Thelinesconnectingthedatapointsareforeaseofveiwing. 8
Open at page →
Page 21
50 I \ ^ I I I I I 1 1 \ \ IMin i \ \ I I I I I I 0.01 0.10 1.00 10.00 Half-ValueLayer(mmCu) Fig.4-3.Graphofthehomogeneitycoefficientagainstthehalf-valuelayermeasuredincopper fortheM,HandSbeamqualities.Thelinesconnecting...
Open at page →
Page 22
Table4-2.Mammographyx-raybeam-qualityparameters Beam Tube Additional Half-Value Homogeneity Code' Voltage Filtration'' Layer'' Coefficient (kVp) (mm) (mmAl) (Al) MoAnode Mo/Mo23 23 0.032Mo 0.271 70 Mo/Mo25 25 0.032Mo 0.2...
Open at page →
Page 23
1.0 0.2 I ^ L_ \ \ \ 1 \ 1 \ 1 20 25 30 35 40 45 ConstantPotential(kV) Fig.4-4.GraphoftheHVL'softhemammographybeamquahtiesversusconstantpotential. 11
Open at page →
Page 24
Table4-3.ISOX-RayBeamQualityParameters Beam AddedFiltration(mm)" FirstHVL SecondHVL Code' Al Cu Sn PbmmAlmmCmmAlmmCu HKIO 0.04 0OS HK20 0 1s U.1J 0.13 016 HK30 0.39 0SQ HK60 'X1Q 0.08 011 U.11 HKIOO ^on 01s 0.31 046 HK20...
Open at page →
Page 25
5.Designphilosophyandtheory X-raycalibrationsareperformedbyusingthesubstitutionmethod.Usingthismethod,theair kermaorair-kermarateisdeterminedatsomepointinspacebyafree-airchamber.The instrumenttobecalibrated isthenplaceda...
Open at page →
Page 26
Table6-1.DescriptionoftheNISTx-raysystems. Features Unipolar^ Bipolar'' Mammography Manufacturer Pantak Pantak Gulmay Outputvoltage(kV) 5to100 5to320 5to50 Outputcurrent(mA) 0.5to80 0.5to30 0.1to40 Outputpower(kW) upto3....
Open at page →
Page 27
Telescope Leadand steel housing I Safetyshutter Beamaperture Test chamber Monitorchamber X-raybeam ~ cehTerrme Beamdefining filter X-raytube Timingshutter Movable supportcarriage Fig.6-1.Schematicof300kVx-rayrange. Colli...
Open at page →
Page 28
HVplate Guardwires1cmspacings Diaphragm X-ray beam Guardplate Steelboxleadlined Collectorplate Fig.6-3.SchematicofWyckoff-Atix free-airionizationchamber. toelectrometerorground I I I Guard plate Diaphragm X-ray beam Coll...
Open at page →
Page 29
SectionalSideElevation 1--- 11 - Fig.6-5.Schematiccross-sectionalviewsoftheLampertifree-airchamber. 1.Leadtomeasuringsystem,2.leadtothermistorreadout,3.thermistor,4.brasscollectorplate, 5.brassguardplate,6.brassguardring...
Open at page →
Page 30
Beam defining aperture Signal Collectingelectrode Exit MoveablePlate Guard Sensitivecollectingvolume Entrance HVbias ushrod Steppingmotorslide2 Fig.6-6.SchematicofAttixfree-airchamber. tocompensateforthedownstreamlossofe...
Open at page →
Page 31
6.3Calculationofairkerma Forafree-airionizationchamberwithvolumeV,theair-kermarateisdeterminedbytherelation K-^—T^^i (6-1) "air ciair where K^ theair-kermarate(Gy/s), I y = themassionizationcurrentmeasuredbythestandard(C...
Open at page →
Page 32
6.4Wyckoff-Attix(50kVto300kV)free-airionizationchambercorrections Thecorrectionforelectronlossis K = \-ILA^jm (6-4) andthecorrectionforscatteredphotoncontribution is k^- \- (6-5) Inequation(6-4),E,.isthepercentelectronco...
Open at page →
Page 33
Table6-4.Comparisonofx-raybeamfiltrationsusedfordatareportedinref[3]withtitrations presentlyusedforconventionalcalibrationconditions Reference[3] X-ray NBSSP-250 tube Inherent potential filter Pb (kV) (mm) (mm) AddedFilt...
Open at page →
Page 34
Table6-5.DatausedtocomputecorrectionsfortheWyckoff-Attixstandardfree-airchamber forconventionalcalibrationconditions BeamCode 100(1- SAp lOO(l-kp) SApS. ^k^/k, M60 1.0203'' 0.77 0.9924 1.0140 MlOO 1.0097 0.60 0.9940 1.00...
Open at page →
Page 35
Table6-6.Comparisonofthe valuescurrentlyusedtothosevaluescomputedfromtheleast squaresequation BeamCodeHVL(mmCu) Present LeastSquares M60 0.052 1.0203' 1.0128 MlOO 0.20 1.0097 1.0100 M150 0.67 1.0068 1.0076 M200 1.69 1.00...
Open at page →
Page 36
Table6-7.Productsofallair-kerma-rate-independent correctionsfortheWyckoff-Attix free-air ionizationchamber BeamCode nk/k. Current nk/k^ Review DifferenceiVo) M60 1.0140 1.0074 0.65 MlOO 1.0052 1.0059 -0.07 M150 1.0058 1....
Open at page →
Page 37
thedefinedbeaminitsentiretyisinterceptedbythefree-airionizationchamberatthetwo measurementpositions.Theratioofthecurrentsmeasuredatposition 1andposition2istheair attenuationcorrectionfactorfortheconditionsofmeasurement.T...
Open at page →
Page 38
occursonlyattheupperendofthex-rayenergyrangeforwhichthisfree-airionizationchamber isused.Therefore,onlyfigures10and14ofRef6arerequiredforcalculationofthe correctionsforbeamcodesS75andLI00.Thesedata,usedinconjunctionwitht...
Open at page →
Page 39
1doieD-1u.SummaryofcorrectionsfortheRitzfree-airionizationchamber Beam AddedAl HVL Code filter (mmAl) 1a ka K nkj (mm) L20 U 0.071 0.9933 1.0000 0.9933" L30 0.265 0.22 0.9942 1.0000 0.9942" L40 0.50 0.49 1.0257 0.9949 1....
Open at page →
Page 40
fornormalroomtemperatureandpressure.Thisisaveryconservativestatementbecausethe assumptionsarethattheentireenergyofthehighestenergyphotonistransferredtoanelectron, andthattheCSDArangeisequaltothepracticalrange.Accordingto...
Open at page →
Page 41
ThecorrectionspresentlyusedfortheLampertichamberaregiveninTable6-12where mostoftheairattenuationcorrectionsareshowntobedependentontemperatureandpressure andthecorrectionsforphotonscatterhavebeencomputedfromtheequationfor...
Open at page →
Page 42
chamberforeachavailableaperture.Table6-13liststhephotonscattercorrectionsfora1cm aperture.TherecombinationcorrectionwasdeterminedusingtheproceduresuggestedbyScott andGreening[9].Therecombinationcorrectioniscalculatedfrom...
Open at page →
Page 43
plateconfiguration. Forroutinemeasurements, thedefiningpointoftheAttixchamber,ispositionedatone meterfromthefocalspotofthex-raysource.However,forthedeterminationoftheHVL'sand theairattenuationcorrections,thedefiningpoint...
Open at page →
Page 44
Table6-14.ResultsofthecomparisonoftheLampertistandardwiththeBIPMstandard Generatingpotential Half-valuelayer NIST/BIPM (kV) (mmAl) 1998 10 0.036 0.9950 30. ; 0.176 0.9961 25 0.250 0.9968 50(b) 1.021 0.9948 50(a) 2.257 0....
Open at page →
Page 45
Table6-17.ComparisonoftheRitzchambertotheNPL50kVstandard Generatingpotential (kV) Half-valuelayer (mmAl) NIST/BIPM 1998 20 0.15 0.9977 24 0.25 0.9978 34 0.35 0.9989 41 0.5 0.9973 44 0.7 0.9983 50 1.0 0.9983 Table6-18.Com...
Open at page →
Page 46
Table6-20.Recent"in-house"comparisonsstandards Beamquality Half-valuelayer Ritz/Attix Lamperti/Attix Mo/Mo23 0.271 0.998 Mo/Mo25 0.296 0.997 0.998 Mo/Mo28 0.332 0.997 0.999 Mo/Mo30 0.351 0.999 0.997 Mo/Mo35 0.392 0.998 0...
Open at page →
Page 47
7.0Gamma-rayairkermastandardsandcalibrationranges Therearesevengamma-raysourcesavailableforthecalibrationofinstrumentsforthe quantityofairkermaandfordeliveringknownexposurestopassivedosimeters.Thesourcesare collimatedand...
Open at page →
Page 48
7.2Gamma-raysources Thelocation,nominalactivity,andorientationofthegamma-raysourcesusedfor instrumentcalibrationsaregiveninTable7-2.Figure7-1isaschematicofairradiatorhousing a''Cogamma-raysourcetypicalofthehorizontalgamm...
Open at page →
Page 49
7.3Calibrationofgamma-raybeams Thehorizontalbeamcalibrationrangeswerecalibratedatvariousdistancesfromthe sources.Thedatawerefittoasuitablefunctionwhichallowsaccuratecomputationofairkerma ratesatselecteddistances,orofdist...
Open at page →
Page 50
''CosourcelocatedinB034,thereferencedistanceontheAl-channelmountedscaleis100cm. Theoffsetofthescale-zerofromthesourcecenteris47.9cm.Thehighestactivity^°Cosource availableforcalibrationworkislocatedinB036.Attheendof1989,t...
Open at page →
Page 51
electrodesareweakenedandcarbonisdepositedonthehigh-voltageinsulator.The1cm\10 cm^and30cm^chambersareparticularlypronetothisproblemsincetheelectrodeshave diameterslessthan1mmand,withthepresentstemdesign,aredifficulttoanch...
Open at page →
Page 52
Intheaboveequations,theK'sareconstantsandtheSDisthealuminumchannelscalereading incm.TheconstantsforeachsourcearelistedinTable7-5.Radiographsofthesebeams indicatea"hot"spotinthecentersoaconservativecomputationfortheuseful...
Open at page →
Page 53
Table7-6.Beamsizedefinedby50%radiographicdensitycontourforvertical-beamgamma- raysources,forspecificcollimatorsettings Source Room Scale Collimator Beam Location Distance settings size (cm) (cm') (cm) ^"Cs B036 38 10.5X...
Open at page →
Page 54
8.2.Electrometers TheKeithleyModel616electrometer'wasusedformanyyearsbytheNISTRadiation InteractionsandDosimetryGroupduetotheversatilityandtheabilitytouseexternalcalibrated capacitors.Keithleyoffersseveralothermodels,the...
Open at page →
Page 55
(YSI).ThesensorsareconnectedtoYSImodel43TNreadouts.TheYSIreadoutisabridge circuitwhich,whenunbalanced,providesavoltageproportionaltothetemperature.Thereare fourYSItemperatureprobesusedinconjunctionwithmeasurementsonthe10...
Open at page →
Page 56
shutter.Theleadthicknessinthetimingshutterwasminimizedformechanicalpurposesbutis ofsufficientthicknesstopreventsignificanteffectsoninstrumentreadingsintheinterval betweenoperationofthetwoshutters. Thechargemeasurementsar...
Open at page →
Page 57
Table8-3.High-energyPantakunitvoltagecalibration NominalVoltage olopeY-Intercept 50 0.222 40.456 55 0.193 40.503 60 0.176 40.500 70 0.146 40.491 80 0.129 40.455 100 0.102 40.431 110 0.084 40.449 120 0.084 40.432 125 0.07...
Open at page →
Page 58
Table8-4.Temperatureprobeparametersforthegammasourcecalibrationranges Temperatureprobe location slope intercept B021-B -0.201 42.830 B021-A -0.202 42.974 B015A -0.095 29.767 B015B -0.094 29.855 B036 1.006 -0.296 B034 1.0...
Open at page →
Page 59
potentialfromthevoltagesourceisincreaseduntiltheimageofthestringcoincideswiththe zeromarkingonthescale.Thepotentialisrecordedfor"VO"ontheindexcardand,decreasing thepotential,dataarerecordedforthe(20,40,50,60,80and100)%of...
Open at page →
Page 60
9.3.Pressureindicatorcalibrations Ananeroidbarometer,WallaceandTierman,ModelFA139,SerialNumberXXI1242, aswellasvariousotherlaboratoryreferencebarometersareperiodicallycalibratedbytheNIST ProcessMeasurmentsDivision.Calibr...
Open at page →
Page 61
Aftertheinstrumenthasbeencahbratedthecalibrationreportisgenerated.Currentlythe reportsaregeneratedinWordPerfectorMicrosoftWord. Templatesareavailabletosimplifythis procedureandtoensureconsistencyinthereportingformat.Samp...
Open at page →
Page 62
10.2.1.2.X-raycalibrations X-raycalibrationsareperformedusingthesubstitutionmethod:thestandardisusedto measuretheexposurerateatagivenpointinspace,thentheinstrumenttobecalibratedisplaced atthatpointandexposedtothesamecali...
Open at page →
Page 63
10.2.1.3.Gamma-raycalibrations Theinstrumentstobecalibratedusinggamma-raybeamsarecalibratedinessentiallythe samewayasinthex-raybeams.Theprimarydifference isthatinthegamma-raybeams,aNIST standardisnotusedatthetimeofcalibr...
Open at page →
Page 64
10.2.2.3.Gamma-raycalibrations Thistypeofcalibration isbasicallythesameasforx-rays,andessentiallynodifferent fromthegamma-raycalibrationofcondenserchambers. 10.3.Calibrationofcurrent-typeinstruments Backgroundinformation...
Open at page →
Page 65
reproducibilityanddecidewhetherthecurrentvalueisacceptable. Forthegamma-rayandx-raycheckchambers,arecordismaintainedofallcalibrations, andthepreviouscalibrationsarecomparedwiththecurrentcalibrationtodetectanytrendor meas...
Open at page →
Page 66
10.6.Irradiationofpassiveandelectronicdosimeters 10.6.1Generalconsiderationsandprocedures DosimetersreceivedatNISTforirradiationintermsofairkermaorexposurearethetypeused forpersonnelprotection.Theairkermafromx-rays,''^Cs...
Open at page →
Page 67
11-1.Uncertaintyanalysisfortungstenxandgamma-rayair-kermarates,shownin% Gamma-raybeam X-raybeam Uncertaintycomponents TypeA TypeB TypeA TypeB airdensity 0.01 0.08 0.01 0.08 charge 0.03 0.1 0.12 0.06 humidity 0.07 0.07 vo...
Open at page →
Page 68
Table 11-2Uncertaintyanalysisforgamma-raycalibrations,shownin% Current-type Condenser Passivedosimeters Uncertaintycomponents TypeA TypeB TypeA TypeB TypeA TypeB airkermarate 0.08 0.38 0.08 0.38 0.08 0.38 airdensity 0.01...
Open at page →
Page 69
Table 11-4Uncertaintyanalysisformammography calibrations,shownin% Uncertaintycomponents TypeA TypeB airkermarate 0.31 0.29 charge 0.12 0.06 airdensity 0.10 0.08 humidity 0.05 distance 0.02 quadraticsum 0.33 0.31 combined...
Open at page →
Page 70
tomaintainoptimalconditions.Table 11-6givesasummaryofexpandeduncertaintiesforeach typeofcalibration. Table11.6Summaryofexpandeduncertainties TungstenX-raysandGammaRaysMammographyX-rays airkermarate 0.8% airkermarate 0.9%...
Open at page →
Page 71
range,alightbeamisusedforprotection.Inaddition,atime-delaydeviceinsidethe300kV x-rayrangemustbeactuateduponleavingortheshuttercannotbeopened.Asafurther indicationofradiationdanger,tworedlightsareturnedonwhenevertheshutte...
Open at page →
Page 72
REFERENCES 1.Marshal,J.L.,ed.NISTCalibraitonServicesUsersGide,NIST(U.S.)Spec.Publ.250;1998 January.Availableon-line:http://www.ts.nist.gov/calibrations. 2.Boutillon,M.andPerroche-Roux,A.M.,Re-evaluationoftheWvalueforelec...
Open at page →
Page 73
x-rays.Characteristicsandmeasurementprocedures,"ReportRT/PROT(83)27, LaboratoriodiMetrologiadellaRadiazionilonizzaniENEA,CRECasaccia,c.p.2400 Roma,Italia,1984. 16.Bums,D.T.,Lamperti,P.andO'Brien,M."ComparisonoftheNISTand...
Open at page →
Page 74
AuroraRoad,Cleveland,OH44139(1977). 30.InstructionManual,Model642Electrometer,KeithleyInstruments,Inc.,28775Aurora Road,Cleveland,OH44139(1980). 31.Rutkowski,G.B.,HandbookofIntegrated-Circuit OperationalAmplifiers,Prenti...
Open at page →
Page 75
Attachment 1 :X-RayBeamQualitiesofferedatNBSPriorto1986
Open at page →
Page 76
1dulcr\-1 . X-raybeamqualitiesofferedatNBSpriorto1986 LightlyFilteredX-Rays Beam Constant Distance Added Half-ValueLayer Homogeneity Code roiennai Filter^' Coeriicient V ; (mmAl) (mmAl) (Al) 10 75 0 0.03 nTO U./y 1J 0 0....
Open at page →
Page 77
Attachment2 :Additionalreferences -databooks
Open at page →
Page 78
ThereferenceslistedinthisattachmentareNISTregisteredlaboratorydatabooks(DB)or binderswhicharelocatedinB033oftheRadiationPhysicsbuilding.Thereferencesare identifiedbythedatabookidentificationnumberandthepagenumber. 1.DB84...
Open at page →
Page 79
Attachment3 :Attixchamberschematics
Open at page →
Page 80
.21.27cm ChamberCenter 1mfromSource -^1.27cm Fig.A3-1.Attixchamberconfigurationforhalf-valuelayerandairattenuationmeasurements. 68
Open at page →
Page 81
ChamberCenter 21.27cmfromAperture Aperture 1mfromsource 15.5cm Fig.A3-2.Attixchamberconfigurationforthetwosmallestpositionsofroutinecalibrations. ChamberCenter 21.27cmfromAperture Aperture 1mfromsource 8cm 25cm " 10.5cm'...
Open at page →
Page 82
Attachment4 :Thehistoryofthemeasurementofcurrent 70
Open at page →
Page 83
Untilhigh-gainnegative-feedback ampHfierswereintroduced,electrometersusedfor ionizationcurrentmeasurementswereusedasnulldetectors.Charge,orcurrent,wasmeasured bymanuallynullingthesignalonthemostsensitiverangeoftheelectro...
Open at page →
Page 84
Fig.A3-1 .Circuitofanegative-feedback amplifierwithresistivefeedback.
Open at page →
Page 85
Forlow-currentmeasurementshigh-megohm(MQ.)resistorsarerequired.Forexample, afeedbackresistorof20Mflisrequiredtodevelopafeedbackvoltageof1Vforthe exceptionallylargeionizationcurrentof50nA.DayandAttix[24]foundthatthehigh-m...
Open at page →
Page 86
gainmaybeashighas50000. Fig.A3-2.Circuitofanegativefeedbackamplifierwithacapacitivefeedbackelement.
Open at page →
Page 87
Attachment5 :Typicalionizationchambercalibrationreport
Open at page →
Page 88
NationalInstituteofStandardsandTechnology REPORTOFAIR-KERMACALIBRATION OF ADDRESS 1 ADDRESS2 ADDRESS3 RadiationDetectionChamber:Make,Model,SN MeasurementsperformedbyMichelleO'Brien ReportreviewedbyPaulLamperti Reportappr...
Open at page →
Page 89
NationalInstituteofStandardsandTechnology REPORTOFAIR-KERMACALIBRATION OF ADDRESS 1 ADDRESS2 ADDRESS3 RadiationDetectionChamber:Make,Model,SN Chamberorientation:thecavitywaspositionedinthecenterofthebeamwiththestemofthec...
Open at page →
Page 90
ConventionalCalibrationConditions forX-andGamma-RayMeasuringInstruments OCell11 code AdditionalFiltration ^ Half-valuelayer Homogeneity coefficient i^llCL'llvc energy Al (mm) Cu (mm) Sn (mm) Pb (mm) Al (mm) Cu (mm) Al Cu...
Open at page →
Page 91
ExplanationofTermsUsedintiieCalibrationProceduresandTables AirKerma :Theair-kermarateatthecalibrationpositionismeasuredbyafree-airionizationchamberfor Xradiationandbygraphitecavityionizationchambersfor^"Coand''^Csgammara...
Open at page →
Page 92
Useofthechamberatotherpressuresandtemperaturesrequiresnormalizationoftheioncurrentstothese referenceconditionsusingthenormalizingfactorF(seebelow). EffectiveEnergy :Theeffectiveenergyisshownforthosebeamswhereitisconsider...
Open at page →
Page 93
Attachment6:TypicalTLDcalibrationreport
Open at page →
Page 94
NationalInstituteofStandardsandTechnology REPORTOF'''CsIRRADIATION OF ADDRESS 1 ADDRESS2 ADDRESS3 MeasurementsperformedbyRonnieMinniti ReportreviewedbyPaulLamperti ReportapprovedbyStephenM.Seltzer FortheDirector National...
Open at page →
Page 95
NationalInstituteofStandardsandTechnology REPORTOFCsIRRADIATION OF ADDRESS 1 ADDRESS2 ADDRESS3 DosimeterType: BadgeOrientation: frontfacenormaltotheincidentradiation. AirKermaRate:X.XXEOGy/s. TLDIdentification Exposed To...
Open at page →
Page 96
Attachment 7:Typicalelectrometercalibrationreport 84
Open at page →
Page 97
NationalInstituteofStandardsandTechnology REPORTOFTEST OF ADDRESS 1 ADDRESS2 ADDRESS3 Electrometer:Make,ModelSN MeasurementsperformedbyMichelleO'Brien ReportreviewedbyPaulLamperti ReportapprovedbyStephenM.Seltzer Nationa...
Open at page →
Page 98
THESP250SERIESONNISTMEASUREMENTSERVICES* SP250-1 SpectralRadianceCalibrations PB87179883 SP250-2 FarUltravioletDetectorStandards PB87227609 SP250-3 RadiometricStandards intheVacuumUltraviolet PB87227625 SP250-4 FrickeDos...
Open at page →
Page 99
THESP250SERIESONNISTMEASUREMENTSERVICES*-Continued SP250-45 RadiationProcessingDosimetryCalibration Services:ManualofCalibrationProcedures SN003-003-03514-9, PB98-140981 SP250-46NISTMultifunctionCalibrationSystem SN003-0...
Open at page →
Page 101
TechnicalPublications Periodical JournalofResearchoftheNationalInstituteofStandardsandTechnology—ReportsNISTresearchand development inthosedisciplinesofthephysicalandengineeringsciences inwhichtheInstituteisactive. These...
Open at page →