Measurement function
The function whose output value, computed from the input quantity values, is the measured value of the output quantity — Y = f(X₁, …, Xₙ) when…
Global Search
One query across documents (page by page), definitions, standards, questions, news, tools and training.
63 results for “Measurement function”
The function whose output value, computed from the input quantity values, is the measured value of the output quantity — Y = f(X₁, …, Xₙ) when…
…Transmittance, on a logarithmic scale, as a function of wavelength of the MAP (Measurement Assurance Program) filters ....................................................................................55 Figure C4. Measured spectral transmittance of…
…is the measured SPRT resistance or resistance ratio at the triple point of water [TPW, (273.16 K)]. For the deviation functions, ΔW = W…
…The measured spectral reflectance factor is a convolution of the true reflectance factor and the normalized bandpass function. At each wavelength point, measured reflectance…
…Ithasthereforebeenthesubjectofcontinuinginvestigations todecreaseandassessuncertainties andtoincreaseitsefficiency.Recent improvements intheprocessarethedetermination ofthesystemresponse linearity, thepolarizationcharacterization ofinstrumentandsources,and accurate measurement ofthespectroradiometer spectral responsivity function. Thethermodynamic temperatureofmeltinggoldremains asthe chiefsourceofuncertainty inthescalerealization. Thecalibratedlampstandardsofspectralradianceareprovidedtothe userwithareportofcalibrationandanattachmentwhichbrieflydescribes…
…0,(A„A)^z(\-Ay0,,(A), (3.6) wheretheslit-scattering functionz{A(^-A) isdependentonlyonthedifferencebetweenthe wavelength settingofthemonochromator andthewavelengthoftheflux(power)andthe "spectralflux"factor0^^isdependentonlyonthewavelengthoftheflux.Thefactor <Z…
…The SPRT resistance is measured at the argon triple point (ArTP), the mercury triple point (HgTP), and the WTP. The deviation function for this…
…j ����τ � . (21) For transmission density as a function of the measured signals, the first measurement equation is obtained by substituting E qs. (18…
…CIE V(λ) function. Radiometry concerns physical measurement of optical radiation as a function of its wavelength. As specified in the definition of the…
…previous reference instrument, the Spectral Tri-function Automated Reference Reflectometer (STARR), are described. Examples of calibration measurements, including specular reflectance of mirrors, bidirectional reflectance…
Questions post under a public pseudonym. Be specific — instrument, method, standard.