Global Search

Search Metrology Atlas

One query across documents (page by page), definitions, standards, questions, news, tools and training.

24 results for “Relative standard measurement uncertainty

A standard uncertainty divided by the absolute value of the measured quantity value — the form specifications and CMCs often quote (parts in 10⁶, percent…

VIM (JCGM 200:2012) 2.32

…Calculate the correction for each instrument parameter (temperature, barometric pressure, relative humidity as applicable), C x, using the correction for the reference standard, C…

Page 5 · SOP 49 · May 2019 Open PDF at page 5 →

…Example uncertainty budget table. Uncertainty Component Description Symbol Source Typical Distribution Uncertainty of the standard mass(es) (5.1) u s Calibration certificate Expanded…

Page 16 · SOP 14 · May 2019 Open PDF at page 16 →

uncertainty for the measurement is based upon the uncertainty for the measurement process used and the uncertainty associated with the environmental measurement standards. The…

Page 5 · SOP 2 · May 2019 Open PDF at page 5 →

…Freedom Relative Humidity Volume standard(s) data: Identification (enter interval if needed) Nominal Calibrated Volume Volume Correction Coefficient of Expansion Exp. Uncertainty k factor…

Page 9 · SOP 16 · May 2019 Open PDF at page 9 →

…4 Calibrated hygrometer with sufficiently small resolution, stability, and uncertainty (see SOP 2, e.g., accurate to ± 10 percent) to determine relative humidity. 4…

Page 4 · SOP 5 · May 2019 Open PDF at page 4 →