Inside SOP 4: double substitution, the workhorse of mass calibration
Ask a mass laboratory how it actually compares an unknown weight to a standard and the answer, most of the time, is double substitution — the procedure NIST documents as SOP 4 in the library here.
The idea is to make the balance a comparator rather than a scale. The standard and the unknown are weighed in an S–X–X–S sequence on the same balance within a few minutes, so the result depends on the small observed differences, not on the balance's absolute calibration. Drift that is linear in time largely cancels; a sensitivity weight converts the difference readings into mass units. The companion single-substitution procedure (SOP 7) trades a little uncertainty for speed by halving the observations.
The practical judgment is choosing when each design is enough: echelon of the weights, the tolerance being defended, and whether air buoyancy corrections are applied all feed that choice. The full procedure — including the data reduction and the uncertainty treatment — is in the library, page-searchable, with OIML R 111 defining the weight classes the results are judged against.
The idea is to make the balance a comparator rather than a scale. The standard and the unknown are weighed in an S–X–X–S sequence on the same balance within a few minutes, so the result depends on the small observed differences, not on the balance's absolute calibration. Drift that is linear in time largely cancels; a sensitivity weight converts the difference readings into mass units. The companion single-substitution procedure (SOP 7) trades a little uncertainty for speed by halving the observations.
The practical judgment is choosing when each design is enough: echelon of the weights, the tolerance being defended, and whether air buoyancy corrections are applied all feed that choice. The full procedure — including the data reduction and the uncertainty treatment — is in the library, page-searchable, with OIML R 111 defining the weight classes the results are judged against.
Sources — reference chain
Every claim traces to an authoritative reference; Atlas standards entries link onward to the official publisher.
SOP 4 — Double Substitution
Atlas library — full text, page-searchable (18 pages, May 2019)
ATLAS LIBRARY
SOP 7 — Single Substitution
Atlas library — full text, page-searchable (15 pages, May 2019)
ATLAS LIBRARY
OIML R 111-1:2004
Weights of classes E1, E2, F1, F2, M1, M1–2, M2, M2–3 and M3 — Part 1: Metrological and technical requirements — Atlas entry → official source at www.oiml.org
ATLAS INDEX
More news
Inside SOP 30: building your first measurement assurance program
Aug 28, 2026
VIM concept: verification and validation, one letter and one question apart
Aug 27, 2026
Force explainer: from deadweight machines to strain-gauge cells
Aug 26, 2026
Inside SOP 1: what belongs on a calibration certificate
Aug 25, 2026